Ultrasonic flowmeter

Reference number
Coordinator AccessGate Aktiebolag
Funding from Vinnova SEK 500 000
Project duration November 2012 - May 2013
Status Completed

Purpose and goal

The target of the project is to develop a battery-powered MID-approved water meter that uses ultrasonic measurement to measure the flow of water. Prototypes of the meter have been tested according to the requirements specified in the MID standard, i.e. EN 14154-1 and OIML R49, 2006. The test shows that the tested meters meet the accuracy within each flow range specified by the standard.

Results and expected effects

The work shows that the design of the meter as well as the method of measurement works well, and that the accuracy of the meters falls within the requirements defined by MID.

Approach and implementation

The work has been performed by generation of prototypes. Selected prototypes have been tested for flow accuracy. From a series of 20 prototypes, 3 meters have randomly been selected for testing. The limited number of tested meters allows the test result to be tainted with some uncertainty, the test should therefore be extended to a larger number of test items.